Microprocessor‑controlled stroke accuracy
On‑board logic adjusts position in real time, holding valve setpoints within 0.5% of full stroke even under fluctuating line pressure.
Our smart actuators, linear drive cylinders, and Modbus transmitters are built to handle the demands of continuous water treatment — from precise chemical dosing to reliable gate valve operation in harsh environments.
Each actuator integrates a dedicated microcontroller for real-time position control, fail-safe logic, and configurable stroke limits. The EC-2000 series delivers 2000N thrust with 4-20 mA feedback, enabling precise modulation of quarter-turn and multi-turn valves in filtration and dosing lines.
Benefit: Eliminates mechanical drift and reduces manual recalibration cycles.The LD-1500 cylinder provides 1500 N continuous force for operating large gate and sluice valves. Its stainless-steel construction and non-contact magnetostrictive sensor (0.1 mm resolution) ensure reliable performance in humid, chemical-laden plant atmospheres.
Benefit: Maintenance-free operation over 1 million cycles with direct valve yoke mounting.MT-485 transmitter converts analog signals (4-20 mA, 0-10 V, potentiometer) to isolated Modbus RTU over RS-485. Supports up to 247 nodes on a single bus with configurable baud rate and parity, making it straightforward to retrofit legacy actuators into a unified digital control network.
Benefit: Enables centralized SCADA monitoring without replacing existing valve hardware.All our actuation components include built-in position transmitters that provide continuous feedback to the controller. This closed-loop architecture allows the system to compensate for load variations, pressure changes, and wear, maintaining consistent flow rates across the treatment process.
Benefit: Reduces process variability and chemical waste in dosing applications.Each actuator and cylinder is equipped with thermal shutdown and overcurrent protection to prevent damage during stall conditions. Fail-safe positioning logic ensures valves move to a predefined safe state (open/closed/last position) upon power loss or communication failure.
Benefit: Protects downstream equipment and maintains plant safety during faults.Our components are designed for direct mounting on standard valve yokes and DIN-rail enclosures. Pre-configured wiring and configuration software reduce installation time, while diagnostic LEDs on the MT-485 transmitter simplify troubleshooting on site.
Benefit: Minimizes downtime during retrofits and new plant commissioning.Core benefits
On‑board logic adjusts position in real time, holding valve setpoints within 0.5% of full stroke even under fluctuating line pressure.
Every actuator ships with a pre‑configured RS‑485 interface, so your SCADA sees position feedback without extra signal converters or custom wiring.
When power drops, the drive stores the last commanded position and returns to a safe state — no valve drift, no process upset during brownouts.
Sealed, maintenance‑free mechanism rated for 1 million cycles. No grease fittings, no scheduled lubrication — just continuous operation in chemical‑laden air.
Fully sealed enclosure withstands hose‑down wash‑down areas and outdoor installations. Electronics stay dry even when the actuator is submerged during flood events.
Pre‑drilled pattern matches standard valve flanges. No adapter plates or field modifications — bolt on, wire up, and commission in under an hour.
Explore compatible actuators, cylinders, and transmitters designed for automated water treatment flow control.
Microprocessor-controlled actuator with 2000N thrust, IP67 housing, and Modbus RTU for precise valve modulation in chemical dosing and filtration.
View actuator specsStainless steel cylinder delivering 1500 N continuous force for gate valves and sluice gates, with 0.1 mm magnetostrictive position feedback.
View cylinder detailsSignal converter accepting 4-20 mA, 0-10 V, or potentiometer inputs, outputting isolated Modbus RTU for retrofitting legacy actuators into smart networks.